Air conditioning is not cooling it? In addition to the lack of fluoride may also be these reasons

In the hot summer, air conditioning has become an essential cooling tool for everybody. However, many people may encounter such a situation: air conditioning can still run, but it is no longer cooling, the room has been extremely hot. The first thing that most people encounter in such a situation may be the lack of air conditioning and the need to add Freon. But in fact, there are many reasons why air conditioners do not cool, not necessarily due to lack of fluoride. Below, let us take a look at what causes air conditioning not cooling it!

One of the reasons: Freon is not enough (deficiency of fluoride)

Solution: Add Freon

This type of non-refrigeration is mostly caused by air conditioners that have been used for more than three or four years. Most of them are a normal phenomenon. They are used for a long time and cause the normal consumption of air conditioning refrigerants (that is, Freon or the kind of snow we often say). However, this is only reflected in the fact that the air-conditioning is not cooled enough compared with the normal conditions before, and it will not be completely uncooled, because the pressure is not enough, and it will not be too far from the normal value. At this time, you only need to add more; of course, there are also This is a common and relatively easy-to-find cause for snow leaks due to installation reasons or to the machine itself. It is also easier to handle such problems. Use pressure gauges to check pressure, if not enough, then add on the line.

The second reason is that the power of the air conditioner is not enough so that it is not cooled

Solution: Match the power of the air conditioner with the required cooling capacity in the space

This is also one of the common reasons why there is no cooling (poor cooling effect), but there are many reasons for this kind of non-cooling, such as: a large-sized room with a small power air conditioning tube, and some with the air conditioning power and The size of the rooms seems to match, but due to the relatively closed rooms (such as doors and windows open), or the room has a heat source (such as computers will be more) of course, the glass room west is one of the heat source, and so on. This kind of situation is usually easier to ignore. If we can find a reason for this and solve it well, we can not only make the air-conditioner more chilled, but also save electricity and prolong the service life of air conditioners. To solve such problems, generally only from the increase in the number of air conditioners (in order to make the actual required cooling area and air conditioning power can match the cooling area can match); change the conditions of the use of the environment; increase the sealing of the use of the environment; reduce air conditioning Use the heating sources in the environment, etc. to solve the problem of not cooling.

The third reason: the voltage of the power supply is not enough

Solution: Maintain normal supply voltage

Some users, at home always say that the air-conditioning is not cool enough, to check and found normal, checked a few times did not find the problem. Later, at one inspection time, it was finally discovered that the power supply voltage was unstable there, often failing to reach the normal voltage. This phenomenon is particularly likely to occur when peak power is used. The performance of this kind of problem is: When the voltage is normal, the air conditioning and cooling are also normal. When the voltage is unstable, it will affect sometimes the air conditioning is not cold (the internal machine works, the compressor does not work). We must solve the problem by providing a stable voltage.

The fourth reason: air conditioning does not clean and maintain for a long time

Solution: Cleaning and maintenance of air-conditioning, so that a clean outdoor unit can be more late cooling

Having bought air conditioners, everyone thinks that they can enjoy peace of mind. Actually, we still have to maintain our air conditioners in many ways. Among them, there is one of them. Since the outdoor unit is installed outdoors, it is easy for us to ignore it. After a long period of use, the outdoor unit will cause a lot of dust, dirt, and other dirt to be absorbed on the radiator. This results in a poor heat dissipation effect of the radiator. Air conditioning is not cooling. In addition, the long-term carelessness of the air-conditioning maintenance will make the room air unsanitary, more susceptible to air-conditioning diseases, increase the power consumption, shorten the air-conditioning service life.

The fifth reason is that the air temperature is not cooled due to the high ambient temperature

Solution: Change the outdoor environment

This kind of uncooled condition is often encountered when the temperature of the outdoor unit is too high around the enclosed space or the external unit. For example, for the sake of the appearance of a real estate, the outdoor unit is installed in a small hidden space or even a number of outdoor units in a small space, so it is extremely easy because of the small space where the outdoor unit is not air circulation, resulting in radiators scattered There is no way for the heat to flow out and the air conditioner is not cooled. There is a common saying that when the outdoor temperature exceeds 43 degrees, most air conditioners can hardly transfer indoor heat to the outside through the radiator of the outdoor unit, even causing High pressure protection, this will also cause air conditioning not cooling.

Editing summary: In summary, there are many reasons why air conditioning is not cooled. If this happens, and do not rush to find someone to add Freon, it is best to find a professional maintenance personnel to carefully check, find out the reasons, and then find a solution to the problem according to the reason.

air conditioning

Pyramid Screen

Pyramid screen is named by his special pyramid form.Main feature as follows:
 These products screen panels are constructed with two or three 304 or 316 stainless steel wire cloth layers, after compounded and bended, with a steel backing plate combined together. The wire cloth and bottom steel backing plate combined tightly, increase the filtering area 120% to 150% more than hookstrip flat screen, get an better effective.

Pyramid Shale Shaker Screen

Pyramid Shale Shaker Screen,Shale Shaker Screen,Pyramid Screen Shaker,Pyramid Shale Shaker Screen Sizes

Anping Shengjia Hardware Mesh Co.,LTD , https://www.oilshaleshakerscreen.com