Characteristics and technical parameters of anti-corrosion lining PTFE magnetic plate level gauge

The gold-lined PTFE magnetic flap level gauge adopts stainless steel body lining polypropylene (PP) and polytetrafluoroethylene (PTFE) process, which has high structural strength and corrosion resistance, and can be applied to acidic liquids and alkalis such as hydrochloric acid. Liquid and organic solvents. However, it is not suitable for the measurement of concentrated liquids such as nitric acid, chlorine-containing solvents, aromatics, and aliphatics. The side-mounted inner magnetic flap level gauge is made of stainless steel body PTFE and stainless steel (PP), suitable for the measurement of corrosive media.                                                                       
Side-mounted lining type magnetic flap level gauge (PTFE) is suitable for liquid level measurement in corrosive medium and high working temperature. It adopts advanced stainless steel lining PTFE stretch flange new technology, structure Reliable and long lasting. It is the best choice for liquid level measurement of highly corrosive media such as hydrofluoric acid.

The side-mounted lining type magnetic flap level gauge (PP) is suitable for the measurement of inorganic corrosive liquids such as hydrochloric acid and dilute sulfuric acid. It can be close to metal due to the high strength of imported, especially the unique heat preservation of PPR. The product is suitable for outdoor tank level measurement. It will not freeze inside the winter. However, it is worse than the PTFE type with good temperature and pressure resistance. When the temperature and pressure are low, the product is cost-effective.

Users can use the remote transmitter according to the needs of the project, can realize the local digital display, and output the standard remote transmission signal of 4~20mA to meet the needs of recording instruments or industrial process control. It can also be used with magnetic control switches or proximity switches to control the liquid level monitoring or control the liquid inlet and outlet equipment.

The main technical parameters

Measuring range: 300 ~ 5000mm (special order when more than 5000mm)

Display accuracy: ±10mm;

Working pressure: stainless steel lining PTFE: ≤ 2.5MPa;

Stainless steel lining PP: ≤ 1.0Mpa

(The highest pressure of our company can be 25Mpa, see high temperature and high pressure type instrument for details)

Medium temperature: stainless steel lined with PTFE: -20~200 °C;

Stainless steel lining PP: -20~90°C

Medium density: ≥0.5g/cm3;

Dielectric density difference: ≥0.15g/cm3 (measurement boundary)

Medium viscosity: ≤0.4Pa·S;

Process connection: DN20/25 PN1.0 (execution standard HG20592~20635-97), if required other standards can be manufactured according to customer requirements.

Wetted material: PTFE, PP; (selected according to the chemical nature of the medium and the temperature of the use temperature);

Float material: PTFE, PP, stainless steel lined with PTFE.

Related products: metal rotor flowmeter , magnetic flap level gauge , plastic tube float flowmeter